BPJMT - P-220, POTASSIUM CHROMATE
- MSDS: BPJMT
- Manufacturer: FISHER SCIENTIFIC
- Product Name: P-220, POTASSIUM CHROMATE
- National Stock Number: 6810-00N015819
Product Identification
Product ID:P-220, POTASSIUM CHROMATE
MSDS Date:09/06/1989
FSC:6810
NIIN:00N015819
MSDS Number: BPJMT
Responsible Party
FAIR LAWN, NJ 07410
US
Emergency Phone: 201-796-7100;800-424-9300(CHEMTREC)
Info Phone: 201-796-7100
Cage: 1B464
Contractor
Telephone: 201-796-7100
Cage: 1B464
Ingredients
SUBSTANCE IS REPORTABLE UNDER CERCLA SEC 103, NATL
RTECS: 9999999ZZ
(202)426-2675 IN METROPOLITAN WASHINGTON, D.C. AREA
RTECS: 9999999ZZ
BANDAGE SECURELY, BUT NOT TOO TIGHTLY. GET MED ATTN
RTECS: 9999999ZZ
UPPER & LOWER LIDS, UNTIL NO EVIDENCE OF CHEM
RTECS: 9999999ZZ
SALINE UNTIL PH HAS RETURNED TO NORM (30-60 MIN).
RTECS: 9999999ZZ
REMOVE BY GASTRIC LAVAGE/EMESIS. MAINTAIN BLOOD PRESS
RTECS: 9999999ZZ
GASTRIC LAVAGE/EMESIS IF VICTIM IS UNCON. GET MED
RTECS: 9999999ZZ
ADMIN OF GASTRIC LAVAGE/O*2 SHOULD BE PERFORMED BY
RTECS: 9999999ZZ
SEVERITY OF POIS REQS ADMIN OF ANY ANTIDOTE &
RTECS: 9999999ZZ
USE OF DIMERCAPROL HAS BEEN
RTECS: 9999999ZZ
0.3 ML/10 KG) EVERY 4 HRS, INTRAMUSCULARLY FOR
RTECS: 9999999ZZ
DAYS (DREISBACH, HANDBOOK OF POIS, 11TH ED.).
RTECS: 9999999ZZ
STOP LEAK IF YOU CAN DO IT W/OUT
RTECS: 9999999ZZ
& PLACE INTO CLEAN, DRY CNTNRS FOR LATER DISP. KEEP
RTECS: 9999999ZZ
1000 LBS. SARA SEC 304 REQS
RTECS: 9999999ZZ
REPORTED TO LOC EMER PLANNING COMMITTEE & STATE
RTECS: 9999999ZZ
CHROMIC ACID, DIPOTASSIUM SALT; (POTASSIUM CHROMATE) (SARA
CAS: 7789-00-6
RTECS: GB2940000
Fraction By Weight: 99%
OSHA PEL C,0.1 MG/M3 CRO3
ACGIH TLV: 0.5 MG CR/M3; 9293
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
PRLNGD/RPTD
RTECS: 9999999ZZ
CANCERS, GASTROINTESTINAL ULCERS, AND BLOOD CHANGES
RTECS: 9999999ZZ
CHEM REMAINS (AT LEAST 15-20 MIN) IN CASE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:(ACUTE)INHAL: MAY CAUSE SEV NOSE &
THROAT IRRIT, COUGHING, LABORED BRTHG, WHEEZING, CHEST PAIN,
LARYNGITIS, NOSEBLEEDS, & RHINITIS. ALLERGIC BRONCH MAY OCCUR IN
PREVIOUSLY EXPOS PERSONS. SKIN:MAY CAUS E SEV IRRIT,SKIN
ULCERATION,& SENSIT DERM IN PREVIOUSLY EXPOS PERSONS. EYE:CONT
W/CHROMATE DUSTS/SOLNS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:POTASSIUM CHROMATE: GROUP 1 (IARC).
Effects of Overexposure:HLTH HAZ: MAY CAUSE REDNESS, LACRIMATION,
SEVERE IRRITATION & CONJUNCTIVITIS. INGEST: MAY CAUSE NAUS, VOMIT,
VIOLENT GASTROENTERITIS, HYPERTROPHY,& ULCERATION. (CHRONIC)INHAL:
MAY CAUSE CHRONIC RESP T RACT IRRIT W/CONGESTION, HYPEREMIA,&
POLYPS, RHINITIS, NASAL SEPTUM ULCERATION & PERFORATION, GI
DISORDERS, (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: REMOVE FROM EXPOS TO FRESH AIR IMMED. IF BRTHG HAS
STOPPED, GIVE ARTF RESP. MAINTAIN AIRWAY & BLOOD PRESS & ADMIN O*2
IF AVAIL. KEEP AFFECTED PERSON WARM & AT REST. TREAT SYMP &
SUPPORTIVELY. A DMIN OF O*2 SHOULD BE PERFORMED BY QUALIFIED PERS.
GET MED ATTN IMMED.SKIN: REMOVE CONTAM CLTHG & SHOES IMMED. WASH
AFFECTED AREA W/SOAP/MILD DETERGENT & LRG AMTS OF H*2O UNTIL NO
EVIDENCE OF (ING 4)
Fire Fighting
Flash Point:NON-FLAMMABLE
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, HALON, WATER SPRAY OR
STANDARD FOAM. FOR LARGER FIRES, USE WATER SPRAY, FOG/STD FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT
EQUIP.MOVE CNTNR FROM FIRE AREA IF POSS.DO NOT SCATTER SPILLED MATL
W/HIGH PRESS H*2O STREAMS. DIKE FIRE (SUPDAT)
Unusual Fire/Explosion Hazard:NEGLIGIBLE FIRE HAZARD WHEN EXPOSED TO
HEAT OR FLAME.
Accidental Release
Spill Release Procedures:SOIL SPILL:DIG HOLDING AREA SUCH AS LAGOON,
POND/PIT FOR CONTAINMENT. USE PROT COVER SUCH AS PLASTIC SHEET TO
PVNT MATL FROM DISSOLVING IN FIRE EXTING H*2O/RAIN.H*2O SPILL:ADD
SODIUM BISULFITE.ADD SUI TABLE AGENT TO NEUT SPILLED MATL TO PH-7.
(ING 15)
Neutralizing Agent:AGRICULTURAL LIME, SLAKED LIME, CRUSHED
LIMESTONE/SODIUM BICARBONATE.
Handling
Handling and Storage Precautions:DO NOT GET IN EYES, ON SKIN OR
CLOTHING . DO NOT BREATHE DUST .
Other Precautions:MAY BURN BUT DOES NOT IGNITE READILY.
Exposure Controls
Respiratory Protection:SPECIFIC RESPIRATOR SELECTED MUST BE BASED ON
CONTAMINATION LEVELS FOUND IN WORK PLACE, MUST NOT EXCEED WORKING
LIMITS OF RESPIRATOR AND BE JOINTLY APPROVED BY NIOSH/MSHA. CONTACT
NEHC FOR FURTHER INF O REGARDING RESPIRATORS .
Ventilation:PROVIDE GENERAL DILUTION VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOG/FULL LGTH FACESHLD .
Other Protective Equipment:APPROPRIATE PROTECTIVE (IMPERVIOUS) CLOTHING
AND EQUIPMENT. EYE WASH FOUNTAIN AND QUICK DRENCH SHOWER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: CNTRL H*2O FOR LATER DISP. AVOID BRTHG HAZ VAPS, KEEP
UPWIND. EFTS OF OVEREXP: LIVER & KIDNEY DMG,& PULM SENSIT. OCCUP
EXPOS TO SOME HEXAVALENT CHROMIUM CMPDS HAS BEEN RELATED TO AN I
NCR INCIDENCE OF LUNG CANCER. SKIN: MAYRSLT IN CHROMATE
SENSITIVITY. CHRONIC CHROMATE DERM MAY CONTINUE FOR MANY(ING 2)
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:1775F,968C
Spec Gravity:3 @ 18C
pH:BASIC
Solubility in Water:62.9% @ 20C.
Appearance and Odor:ODORLESS, YELLOW SOLID CRYSTALS.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANT MAY REACT VIOLENTLY WITH COMBUST SUBSTANCES (WOOD,
PAPER, ETC.). STRONG OXIDIZERS.
Stability Condition to Avoid:MAY BURN BUT DOES NOT IGNITE READILY.
AVOID CONTACT WITH HEAT, SPARKS, OR OPEN FLAME.
Hazardous Decomposition Products:THERMAL DECOMPOSITION PRODUCTS ARE
HAZARDOUS AND/OR TOXIC OXIDES OF POTASSIUM AND CHROMIUM.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.